|
|
The application of three-dimensional printing technique for the treatment of femoral intercondylar fractures |
ZHANG Rui, LOU Yiting, CHEN Kai, WANG Jianshun, GUO Xiaoshan |
Department of Orthopaedics Trauma, the Second Affiliated Hospital & Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, 325027 |
|
Cite this article: |
ZHANG Rui,LOU Yiting,CHEN Kai, et al. The application of three-dimensional printing technique for the treatment of femoral intercondylar fractures[J]. JOURNAL OF WEZHOU MEDICAL UNIVERSITY, 2017, 47(6): 412-415.
|
|
Abstract Objective: To investigate the clinical outcome of three-dimensional printing technique for the treatment of femoral intercondylar fractures. Methods: Forty eight patients with femoral intercondylar fractures between January 2015 and September 2015 were randomly divided into treatment group and control group. Mimics software was used to reconstruct fracture model and reduction in treatment group, and preoperative plan was designed based on 3D printing model. Control group’s patients underwent traditional treatment. The surgery duration, blood loss, fluoroscopy time and HSS score were collected. Results: The surgery duration in treatment group (61.25±14.28) min was shorter than that in the control group (79.14±18.43) min, blood loss in treatment group (81.74±23.50) mL was less than that in the control group (106.80±22.75) mL while fluoroscopy time also showed better performance (2.10±0.50 vs. 4.10±0.70), and there was significant difference between two groups (P<0.05). After one-year follow up, the knee function in treatment group was better than that in the control group (P<0.05). Conclusion: Three-dimensional printing technique for the treatment of femoral intercondylar fractures can save surgery duration, reduce blood loss to certain extent, and obtaine better clinical outcome compared to traditional treatment.
|
Received: 12 December 2016
|
|
|
|
|
[1] BRETIN P, O’LOUGHLIN P F, SUERO E M, et al. Influence of femoral malrotation on knee joint alignment and intra-articular contract pressures[J]. Arch Orthop Trauma Surg 2011, 131(8): 1115-1120.
[2] INSALL J N, RANAWAT C S, AGLIETTI P, et al. A comparison of models of knee replacement prostheses[J]. J Bone Joint Surg (Am), 1976, 58: 754-756.
[3] PAKUŁA G, SŁOWIŃSKI J, SCIGAŁA K. Biomechanics of distal femoral fracture fixed with an angular stable LISS plate[J]. Acta Bioeng Biomech, 2013, 15(4): 57-65.
[4] RUSSO M, MALEKZADEH A S, HAMPTON C, et al. Reversed contralateral LISS plate for vancouver B1 peripros-thetic femoral shaft fractures[J]. Orthopedics, 2015, 38(6): e467-472.
[5] TACK P, VICTOR J, GEMMEL P, et al. 3D-printing techniques in a medical setting: a systematic review[J]. Biomed Eng Online, 2016, 15(1): 115.
[6] ZENG C, XING W, WU Z, et al. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction[J]. Injury, 2016, 47(10): 2223-2227.
[7] ZENG C, XIAO J, WU Z, et al. Evaluation of three-dimensional printing for internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach: a preliminary report[J]. Int J Clin Exp Med, 2015, 8(8): 13039-13044.
[8] QIAO F, LI D, JIN Z, et al. A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures[J]. Int Orthop, 2016, 40(4): 835-841.
[9] 张立军, 杨占辉. 股骨髁间骨折术后膝关节功能恢复的影响因素[J]. 中国骨与关节外科杂志, 2014, 7(3): 208-212.
[10] 李卫康, 戚浩天, 赵永杰, 等. 影响股骨髁间骨折术后膝关节功能的相关因素分析[J]. 中国矫形外科杂志, 2013, 21(24): 2443-2448. |
|
|
|