|
|
Influence of different intra-abdominal pressure on the electrical activity of the diaphragm and tidal volume for neurally adjusted ventilatory assist |
WU Huayong, ZHANG Weiwen |
Department of Intensive Care Unit, Quzhou People’s Hospital, Quzhou, 324000
|
|
Cite this article: |
WU Huayong,ZHANG Weiwen. Influence of different intra-abdominal pressure on the electrical activity of the diaphragm and tidal volume for neurally adjusted ventilatory assist[J]. JOURNAL OF WEZHOU MEDICAL UNIVERSITY, 2017, 47(3): 225-228.
|
|
Abstract Objective: To evaluate how IAP affects the EAdi and the tidal volume (VT) during NAVA was meaningful to set parameters of clinical ventilation. Methods: Forty-four patients in ICU were enrolled in this study. Inclusion criteria: over 18 years old adult who was going to use mechanical ventilation for over 72 hours at positive end-expiratory pressure (PEEP) 3-5 cmH2O (1 cmH2O=0.098 kPa). IAP was indirectly measured by injecting saline to bladder with 6 hours interval. The dividing line of high IAP and non-high IAP was set as 12 mmHg (1 mmHg=0.133 kPa) according to WSACS. By a EAdi catheter via nose EAdi was recorded with VT hourly. Results: EAdi was significant lower when IAP was over than 12 mmHg; and VT was significant higher when IAP was less than 12 mmHg. Conclusion: The changes of EAdi and VT under different IAP during NAVA: when IAP was high, EAdi decreases while VT increases and vice-versa.
|
Received: 23 July 2016
|
|
|
|
|
[1] CORDIOLI R L, AKOUMIANAKI E, BROCHARD L. Nonconventional ventilation techniques[J]. Curr Opin Crit Care, 2013, 19(1): 31-37.
[2] STEIN H, FIRESTONE K, RIMENSBERGER P C. Synchronized mechanical ventilation using electrical activity of the diaphragm in neonates[J]. Clin Perinatol, 2012, 39(3): 525-542.
[3] BARWING J, PEDRONI C, QUINTEL M, et al. Influence of body position, PEEP and intra-abdominal pressure on the catheter positioning for neurally adjusted ventilatory assist
[J]. Intensive Care Med, 2011, 37(12): 2041-2045.
[4] 王丽娜, 王妮, 王维霞, 等. 神经调节辅助通气模式在机械通气患者撤机中的应用[J]. 陕西医学杂志, 2015, 44(10): 1369-1370, 1377.
[5] STEIN H, BECK J, DUNN M. Non-invasive ventilation with neurally adjusted ventilatory assist in newborns[J]. Semin Fetal Neonatal Med, 2016, 21(3): 154-161.
[6] SINGH D, MACKEITH P, GOPAL D P. Acute non-traumatic gastrothorax: presentation of a case with chest pain and atypical radiologic findings[J]. Medwave, 2016, 16(2): e6409.
[7] MONDAL P, ABU-HASAN M, SAHA A, et al. Effect of laparotomy on respiratory muscle activation pattern [J]. Physiol Rep, 2016, 4(1): e12668.
[8] ESTRADA L, TORRES A, SARLABOUS L, et al. EMG-derived respiration signal using the fixed sample entropy during an inspiratory load protocol[J]. Conf Proc IEEE Eng Med Biol Soc, 2015, 2015: 1703-1706.
[9] 曹宏. 神经调节辅助通气在ARDS患者中的应用[D]. 天津: 天津医科大学, 2013.
[10] 陈正, 罗芳, 马晓路, 等. 神经调节辅助通气在早产儿呼吸窘迫综合征中的应用[J]. 中国当代儿科杂志, 2013, 15(9): 709-712.
[11] DI M R, SPADARO S, MIRABELLA L, et al. Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV[J]. Crit Care, 2016, 20: 1.
[12] 林玫瑞, 袁琳, 黄雪琴, 等. 腹内压监测在综合ICU的临床观察和应用[J]. 中国实用医药, 2012, 7(9): 30-31.
[13] BELLANI G, COPPADORO A, POZZI M, et al. The ratio of inspiratory pressure over electrical activity of the diaphragm remains stable during ICU stay and is not related to clinical outcome[J]. Respir Care, 2016, 61(4): 495-501.
[14] ASADNIA M, KOTTAPALLI A G, HAGHIGHI R, et al. MEMS sensors for assessing flow-related control of an underwater biomimetic robotic stingray[J]. Bioinspir Biomim, 2015, 10(3): 036008.
[15] HOUTEKIE L, Moerman D, Bourleau A, et al. Feasibility study on neurally adjusted ventilatory assist in non-invasive ventilation after cardiac surgery in infants[J]. Respir Care, 2015, 60(7): 1007-1014.
|
|
|
|