|
|
Clinical application of LAMP and Xpert Mtb/RIF in early detection of pulmonary tuberculosis infection |
ZHANG Weiyang1, ZHONG Jianping1, YANG Guobiao1, JIN Faxiang2, XU Wenfang2, WANG Huajun1. |
1.Department of Infectious Diseases, Shaoxing Municipal Hospital, Shaoxing, 312000; 2.Department of Clinical Laboratory, Shaoxing Municipal Hospital, Shaoxing, 312000
|
|
Cite this article: |
ZHANG Weiyang,ZHONG Jianping,YANG Guobiao, et al. Clinical application of LAMP and Xpert Mtb/RIF in early detection of pulmonary tuberculosis infection[J]. JOURNAL OF WEZHOU MEDICAL UNIVERSITY, 2017, 47(1): 61-63.
|
|
Abstract Objective: To compare the clinical application of DNA loop mediated isothermal amplification (LAMP) technology and Xpert MTB/RIF in early detection of the infectious source of pulmonary tuberculosis. Methods: Three hundred TB sputum samples were detected using Xpert Mtb/RIF detection, MGIT liquid culture and LAMP technology, of which 100 cases of smear-positive specimens, 200 cases of smear-negative specimens. Results: In 100 cases of TB smear-positive specimens, the positive rate was 96.0% with LAMP technology, and the positive rate was 97.0% with Xpert Mtb/RIF detection (P>0.05). In 200 cases of smear-negative specimens, the positive rate was 53.5% with LAMP technology, and the positive rate was 25.0% with Xpert Mtb/RIF detection (P<0.01). Conclusion: In the diagnosis of smear positive specimens, the sensitivity of LAMP technology and Mtb RIF/Xpert was similar. In the diagnosis of smear negative specimens, LAMP technology is better than Mtb Xpert/RIF.
|
Received: 31 May 2016
|
|
|
|
|
[1] 金法祥, 王华钧, 许文芳, 等. 4种新方法快速检测结核分枝杆菌的临床研究[J]. 中国卫生检验杂志, 2015, 25(21): 3638-3639.
[2] 戴广明, 曹以诚, 杜正平, 等. 结核分枝杆菌环介导恒温扩增(LAMP)快速检测方法的评价[J]. 中国防痨杂志, 2011, 33(1): 47-51.
[3] 金法祥, 王华钧, 孙小军. DNA环介导恒温扩增试验检测结核分枝杆菌的研究[J]. 中华医院感染学杂志, 2011, 21(12): 2639-2640.
[4] IWAMOTO T, SONOBE T, HAYASHI K. Loop-mediated isothermal amplification for direct of mycobacterium tuberculosis complex, M.avium, and M.intracellulare in sputum samples[J]. J Clin Microbiol, 2003, 41(6): 2616-2666.
[5] PANDEY B D, POUDEL A, YODA T, et al. Development of an in-house Loop-mediated isothermal amplifyication (LAMP) assay for detection of Mycobacterium tuberculosis and evaluateon in sputum samples of Neaplese patients[J]. J Med Microbiol, 2008, 57(4): 439-443.
[6] LAIFANGBAM S, SINGH H L, SINGH N B, et al. A comparative study of fluorescent microscopy with Ziehl-Neelsen staining and culture for the diagnosis of pulmonary tuberculosis[J]. Kathmandu Univ Med J, 2009, 7(27): 226-230. |
|
|
|