CHEN Chengwang,PAN Xiaoyun,XUE Enxing, et al. Clinical research of measurement of anatomical proximal femor using X ray in equalizing limb length in total hip arthroplasty[J]. JOURNAL OF WEZHOU MEDICAL UNIVERSITY, 2014, 44(9): 678-.
Abstract:Objective: To explore the clinical meaning of measurement of anatomical proximal femor in equalizing limb length in total hip arthroplasty. Methods: From Feburary 2011 to December 2012, 120 patients including 65 males and 55 females underwent unilateral THA. The clinical measurement and radiographic examination were accomplished. The discrepancy of limb length was measured using PACS system in computer, and at the meantime, from the other hip, the angle of the anatomical axis of femur and the line linked the center of femoral head and the top of great trochant was measured. Based on these results, the surgical protocols were designed, the type of hip prosthesis was chosen, and the neck length of femoral prothesis, and the position of osteotomy were estimated. By the proper wearing of the acetabula, the best rotation point was found out. According to the results of radiographic and other examination, the neck length was readjusted after the insertion of the prosthesis so as to achieve intended leg length equalization. The discrepancy of the leg length was measured and evaluated after operation. Results: The incision healed by first intention in all patients. The leg length equalization was got in 108 patients (<0.5 cm, 68 cases; 0.5~1.0 cm, 40 cases), and only 12 limbs had been lengthened more than 1.0 cm. One hundred and two patients were followed up for 15.1 months on average (5~27 months). Setting the results against those before surgery (46.2±7.2), the mean Harris score was 86.5±6.9 points after surgery. Conclusion: With the measurement of the anatomical proximal femor using X ray accompanying other methods before and during operation, the problem of unequal leg length can be well solved in total hip arthroplasty.
[1]Maloney WJ, Keeney JA. Leg length discrepancy after total hip arthroplasty[J]. J Arthroplasty, 2004, 19(4 Suppl 1): 108-110.
[2]García-Juárez JD, Bravo-Bernabé PA, García-Hernández A, et al. Incidence and effect of leg length discrepancy after to-tal hip arthroplasty[J]. Acta Ortop Mex, 2013, 27(1): 43-46.
[3]吕厚山. 人工关节外科学[M]. 北京: 科学出版社, 1998: 177-178.
[4]Mc Williams AB, Grainger AJ, O’Connor PJ, et al. A re-view of symptomatic leg length inequality following total hip arthroplasty[J]. Hip Int, 2013, 23(1): 6-14.
[5]杨勇, 程涛, 张先龙, 等. 全髋关节置换术后双下肢不等长对功能和步态的影响[J]. 中华关节外科杂志(电子版),2013, 7(1): 60-63.
[6]张鹏, 黄勇, 万连平, 等. 数字模板测量在均衡全髋关节置换术双下肢长度中的应用[J]. 中华创伤骨科杂志, 2009,11(8): 722-724.
[7]Shivan S, Christopher I, Matthew K, et al. Digital templating facilitates accurate leg length correction in total hip arthro-plasty[J]. Acta Orthop Belg, 2012, 78(3): 344-349.
[8]Bertz A, Indrekvam K, Ahmed M, et al. Validity and reliabil-ity of preoperative templating in total hip arthroplasty us-ing a digital templating system[J]. Skeletal Radiol, 2012, 41(10): 1245-1249.
[9]李宏斌, 朱振安, 陈雪荣, 等. 髋关节置换术中下肢不等长的预防[J]. 临床骨科杂志, 2011, 14(5): 499-501.
[10]Joseph D, Maratt, Alexander E, et al. Novel method for en-suring leg length in total hip arthroplasty[J]. Orthopedics,2013, 36(4): e401-403.
[11]Alazzawi S, Douglas SL, Haddad FS. A novel intra-oper-ative technique to achieve accurate leg length and femo-ral offset during total hip replacement [J]. Ann R Coll Surg Engl, 2012, 94(4): 281-282.
[12]温宏, 胡月正, 陈成旺, 等. 计算机X摄影测量正常成人下肢负重轴线[J]. 温州医学院学报, 2008, 38(6): 507-509.